Vulnerability management is a challenge even on a good day on the shop floor. Picture a conversation that goes like this: IT asks, "Why haven't you patched that server yet?" while the Plant Head, asks, "Why do you want to reboot my safety controller during peak load?"

If you have come this far, I am confident that you know that the "patch everything immediately" approach is a recipe for unplanned downtime in our world. However, I am sure you are aware that ignoring vulnerabilities is also a recipe for a lasting catastrophe.

IEC 62443, specifically the 2-3 (Patch Management in the IACS Environment) bit provides a much-needed middle ground. It does not demand you patch recklessly; instead, it demands you manage risk defensibly.

In today’s post we take a hard look at how to upgrade your vulnerability strategy from a reactive burden to a proactive defense mechanism that is risk-aware and tailored for the reality of 2026.

As always, before we move forward, don’t forget to check out our previous post on securing OT telemetry in 2026 here.

Understanding the paradigm shift: Defensible deferral

In IT, a missing patch can be categorized as a negligence. In OT, applying a patch that trips a turbine is a category A offence and a possible kinetic crime. IEC 62443-2-3 explicitly recognizes this conflict.

Your goal is not to have zero vulnerabilities (which is a high goal). A more achievable goal instead is what we call Defensible Deferral. This means having a documented, technical justification for why a patch was delayed and what you did instead to control the risk.

Actionable strategy: The IEC 62443 triage matrix

We all know better than treating all CVEs (Common Vulnerabilities and Exposures) equally. Instead a adoption of a triage matrix based on Safety, Availability, and Zone Criticality is recommended.

Scenario

OT risk profile

IEC 62443 action

Critical asset / remote Executable

High Risk

Patch immediately (Open an emergency maintenance window). If patch is unavailable, isolate device immediately.

Critical asset / local access only

Medium Risk

Defer and compensate. Schedule for next outage. Increase physical security and logging on that specific rack.

Non-critical asset / low severity

Low Risk

Monitor. Log the vulnerability in your asset register. Patch during routine lifecycle refresh.

A detailed Note for SMEs: A CVSS score of 9.8 (Critical) on a device buried deep in a secure zone (SL-3) with no external routing is less urgent than a CVSS 7.0 on an Historian sitting in the DMZ. Context is certainly the deciding factor.

When there is no patch (AKA the "forever day" challenge)

In legacy substations and manufacturing lines, you will inevitably find controllers running OS versions that haven't seen a patch since 2015 or since your days in college (whichever is earlier). When a new zero-day hits, the vendor will simply say, "fix coming up in 3 months" and move on.

When you cannot patch and you cannot replace. You must compensate.

Compensating controls checklist (or simply the "Virtual Patch"):

If you cannot touch the firmware/software, you must bubble wrap the asset in layers of armor.

  • Network micro-segmentation: Tighten the firewall rules for that specific IP. If it talks to 5 devices, can we restrict it to 3? (Ref: IEC 62443-3-2 Zones & Conduits).

  • Protocol Sanitization: Use Deep Packet Inspection (DPI) firewalls to block the specific command used by the exploit (e.g., block CIP stop commands from unauthorized IPs) without stopping legitimate traffic.

  • Use an NDR solution to secure traffic inside the perimeter: An NDR solution such as Shieldworkz can secure the traffic by managing threats inside the perimeter

  • Alarm Limits: Tighten process alarms on the DCS/SCADA to catch the effect of an exploitation (e.g., unexpected setpoint changes) even if you can't stop the exploit itself.

  • "Sticky" Notes: Literally and digitally tag the HMI. Operators need to know this asset is "bruised" and requires extra vigilance.

Tracking patches: the "shadow factory"

You cannot manage what you cannot see. Multi-tab spreadsheets will be among the chief enemies of accurate patch tracking in 2026. They are static snapshots in a dynamic threat landscape.

Best practice for tracking:

  1. Automated asset nventory: Use passive listening tools (such as Shieldworkz) that parse protocol traffic to identify firmware versions without active scanning (which risks tripping PLCs).

  2. SBOM integration: Require a Software Bill of Materials (SBOM) from your vendors. You might know you run "Vendor X SCADA," but do you know it uses a vulnerable "Log4j" library underneath? An SBOM can tell you this. Shieldworkz’ consulting team can do a risk assessment and figure this out for you as well.

  3. Vendor feed aggregation: Don't check 50 vendor websites. Use a centralized threat intelligence feed that maps CVEs specifically to industrial hardware.

The 2026 OT security priorities checklist

As we look toward 2026, the "patching treadmill" will only get faster. The European Cyber Resilience Act (CRA) and stricter NERC-CIP mandates are certainly changing the baseline.

Priorities for the Plant Head:

Automated validation (The "Digital Twin" Test)

  • The target: Never install a patch on live production without testing. We all know this but I am just reiterating for sake of understanding

  • 2026 standard: Maintain a virtualized "Digital Twin" of your critical control loops. Automated scripts apply the patch to the twin, run a simulation of 24 hours of production, and flag any anomalies before you ever touch the physical plant.

"Secure by design" procurement

  • The target: Stop importing debt.

  • 2026 standard: RFP requirements must state: "Vendor must provide machine-readable SBOMs and commit to a 72-hour patch notification SLA." No SBOM, no purchase, no negotiation.

Identity as the new perimeter

  • The target: If patching is impossible, access must be impossible for attackers.

  • 2026 standard: Implement MFA (Multi-Factor Authentication) even at the distinct engineering workstation level. If a technician plugs into a switch in the substation, they must authenticate.

4. The "break-glass" recovery plan

  • The target: Resilience over prevention.

  • 2026 standard: Assume the patch fails or the malware gets in. Do you have an offline, immutable backup of the logic files (ladder logic, relay settings) from yesterday? Test your restore times.

Summary for the Asset Owner

IEC 62443 is not a compliance checklist; it is a language of risk.

  • IT says: "This server is vulnerable."

  • You say: "This server controls the cooling loop. The risk of patching (trip) is higher than the risk of exploitation (hack) because of our Compensating Controls (Air Gap plus IPS). We will defer this to the next shutdown."

To offer more help, we are sharing a "plug-and-play" Vulnerability Triage Matrix designed specifically for an OT environment. It moves beyond simple CVSS scores (which are often misleading in OT) and calculates risk based on IEC 62443-3-2 principles (Zones, Conduits, and Security Levels).

1. Threat Context

2. Asset Context (Business Impact)

3. Vulnerability Context

4. Calculated Risk

5. Triage Decision

6. Action Plan

CVE ID / Threat Name

Asset Name & Zone

Availability Requirement

CVSS (Base)

Exploitability in Environment

Final Risk Score

e.g., CVE-2026-1234 (Remote Code Exec)

Safety Controller (SIS) / Zone: Safety

Critical (No Stop)

9.8 (Crit)

Low (Air-gapped, no route)

Medium

e.g., CVE-2025-5678 (Privilege Esc)

Data Historian / Zone: DMZ

Medium (Buffering ok)

7.5 (High)

High (Internet exposed)

CRITICAL

e.g., Vendor "Forever Day" (No Patch)

Legacy HMI (Win XP) / Zone: Control Room

High (Visibility)

8.0 (High)

Medium (Local LAN only)

High

e.g., CVE-2026-9999 (Denial of Service)

Engineering Workstation / Zone: Engineering

Low (Day use only)

5.3 (Med)

Medium (VPN Access)

Low

 

How to use this template (The Logic)

To make this matrix work in Excel, you need to define the logic for Column 4 (Final Risk Score). A seasoned SME does not trust the CVSS score alone.

The "Real Risk" Formula:

Asset Criticality (1-5 Scale)

  • 5 (Safety/Environmental): SIS, Gas Detection, Emergency Shutdown (ESD).

  • 4 (Production Critical): Main DCS Controller, Turbine Governor, Assembly Line PLC.

  • 3 (Production Support): Historian, HMI, Quality Lab systems.

  • 2 (Non-Essential): Training simulator, Dev/Test environment.

  • 1 (Insignificant): Printer, Cafeteria display.

Zone Exposure (Security Level Modifier)

This adjusts the risk based on how "reachable" the asset is (IEC 62443 Zones).

  • High Exposure (1.0): DMZ, Enterprise-connected, Remote Access enabled.

  • Medium Exposure (0.5): Control Zone (Layer 2/3), no direct external route.

  • Low Exposure (0.1): Safety Zone, Air-gapped, or Unidirectional Gateway (Data Diode).

The Decision Logic (Column 5)

  • Score > 20 (Critical): Stop the bleeding. Requires immediate mitigation (Patch or Isolate). Call an emergency Change Approval Board (CAB) meeting.

  • Score 10-20 (High): Compensate. You cannot likely patch immediately, so you must add "Virtual Patches" (Firewall rules, IPS signatures) within 72 hours.

  • Score < 10 (Medium/Low): Manageable. Add to the backlog. Re-evaluate during the next planned outage or monthly window.

Advisory for SMBs: The "compensating controls" tab

In the spreadsheet, create a second tab specifically for compensating controls. When you select "DEFER" or "COMPENSATE" in the main matrix, you must link it to a specific control here to ensure the risk is adequately addressed.

Example entries:

  • Control type: Network Segmentation

  • Implementation: "ACL applied on Switch SW-02 port 4 to block UDP 161 (SNMP) from all IPs except Engineering Station."

  • Verification: Tested by J. Doe on [Date].

Learn more about OT patch management from the experts.

Check out our OT security NDR solution.

Wöchentlich erhalten

Ressourcen & Nachrichten

You may also like

BG image

Jetzt anfangen

Skalieren Sie Ihre CPS-Sicherheitslage

Nehmen Sie Kontakt mit unseren CPS-Sicherheitsexperten für eine kostenlose Beratung auf.

BG image

Jetzt anfangen

Skalieren Sie Ihre CPS-Sicherheitslage

Nehmen Sie Kontakt mit unseren CPS-Sicherheitsexperten für eine kostenlose Beratung auf.

BG image

Jetzt anfangen

Skalieren Sie Ihre CPS-Sicherheitslage

Nehmen Sie Kontakt mit unseren CPS-Sicherheitsexperten für eine kostenlose Beratung auf.