Industrial Control Room Oversight

Use Case

Protecting the Substation Where Solar Generation Meets the Grid

Industry: Renewable energy

No signup required!

Securing Grid-Connected Substations: OT Visibility, Segmentation and Monitoring for Renewable Energy

A cellular modem installed for commissioning was still live at the relay panel, long after the interconnection was complete. Shieldworkz gives renewable energy operators the visibility to find that kind of leftover access, close it, and build the segmentation and monitoring a grid-interconnected substation needs, without interrupting protection functions.

Renewable Energy Substation Security Challenges

Substation engineering and security leaders are being asked to secure interconnection points that commissioning left wide open:

Leftover commissioning access. A cellular modem installed for the commissioning contractor to configure relays remained active long after project handover.

Flat substation LAN. Protection relays, the RTU, and the metering system all shared the same network segment with no separation.

Unmonitored GOOSE traffic. Breaker trip messaging between relays had no authentication and no visibility into whether traffic matched expected patterns.

Unmonitored relay setting changes. Protection relay configuration changes left no record of who made them or when.

Rising NERC CIP classification pressure. As the site's interconnection capacity grew, the substation was approaching an impact rating that would require documented access controls.

Understanding the Renewable Energy Risk Landscape

Solar and renewable interconnection substations are commissioned under tight project timelines, often by contractors who need temporary remote access to configure protection relays before handover. That access is frequently never formally closed. Combined with a flat substation LAN carrying protection, RTU, and metering traffic together, and GOOSE messaging between relays that was never built with authentication in mind, the result is a protection environment with real exposure at exactly the point where generation meets the grid. As interconnection capacity grows, so does regulatory scrutiny , a substation that crosses into a higher NERC CIP impact category must be able to show documented access controls, not just protection logic that happens to be working.

Common Cyber Threats Affecting Renewable Energy Substations

Unreviewed remote access left active after commissioning or project handover

Unauthorized or unattributed changes to protection relay settings

Lateral movement across a flat LAN connecting protection, RTU, and metering systems

Spoofed or manipulated GOOSE messaging between protection relays

Ransomware reaching substation control networks through an exposed access path

Undocumented access failing to meet NERC CIP impact-rating requirements

Loss of visibility into whether an alarm has been disabled rather than simply not triggered

Renewable Energy OT/ICS Security Use Cases

Shieldworkz supports the scenarios renewable energy and substation security leaders face every day, including:

Substation asset visibility into every protection relay, RTU, metering device, and remote access point

Protection relay protection against unauthorized configuration or setting changes

GOOSE and MMS traffic monitoring for anomalies against a modeled baseline of expected behavior

Secure remote maintenance for relay engineers and commissioning contractors

Third-party and contractor access governance, replacing leftover modems with managed, logged connections

Network segmentation separating protection, RTU, and metering traffic into distinct zones

Legacy relay and RTU protection for devices that can't be replaced ahead of a capacity upgrade

Vulnerability management for relay and RTU firmware tied to the leftover access path

Threat detection tuned specifically to configuration and setting changes on protection IEDs

Compliance monitoring aligned to NERC CIP and IEC 62443 zone and conduit practice

Incident response support that traces a protection anomaly back to a specific device and session

Asset discovery across the substation without interrupting protection functions

Continuous monitoring with substation alerts routed to a managed OT SOC

How Shieldworkz Solves Renewable Energy Substation Security Challenges

Shieldworkz delivers an end-to-end substation security program, not a point tool:

Passive Asset Discovery- Every protection relay, RTU, metering device, and remote access point mapped without interrupting protection functions

IEC 62443 Zone & Conduit Model- Zones aligned to substation function, separating protection, control, and metering systems

Network Segmentation- Protection, RTU, and metering traffic separated into distinct zones within the substation LAN

OT Vulnerability Assessment- Relay and RTU firmware reviewed for known exposures tied to the leftover access path

Secure Remote Access- The leftover commissioning modem replaced with a broker-managed, logged connection for authorized relay engineering only

NERC CIP Readiness Assessment- Access control and monitoring gaps assessed against the substation's anticipated impact rating

OT NDR & Continuous Monitoring- GOOSE and MMS traffic watched for anomalies against a modeled baseline of expected substation behavior

Governance Documentation- A change approval and access review process defined for relay setting modifications

Relay Setting Change Detection- Alerts tuned specifically to configuration and setting changes on protection IEDs

OT SOC & Managed Monitoring- Substation alerts routed to a team that reviews protection and control activity around the clock

Threat Intelligence- Informed by the Shieldworkz Threat Research Lab's tracking of risks at grid-interconnection points

Managed OT Security Services- One accountable team across discovery, segmentation, monitoring, and NERC CIP readiness

The Business Value of a Secured Interconnection Point

Closing the access gap and adding monitoring at the interconnection point delivers measurable value well beyond the security team:

Reduced risk of unreviewed access paths reaching protection settings

Increased operational resilience at the point where generation meets the grid

Faster detection of relay setting changes , from no record to logged and attributable

Improved, audit-ready NERC CIP readiness ahead of an anticipated impact reclassification

Lower cyber risk following segmentation of protection, RTU, and metering traffic

Secure support for growing interconnection capacity and future capacity upgrades

Secure Your Interconnection Point

A forgotten commissioning connection doesn't announce itself , it waits to be found during an audit, a capacity review, or an incident. Talk to Shieldworkz about closing leftover access paths and building segmentation and monitoring into your substation, without interrupting protection functions.

Schedule Your Free Consultation with Shieldworkz OT Security Experts

Book Your Consultation Today!

Secure renewable energy substations with continuous OT monitoring and protected grid operations.